HME

Mercury Filled - HART - SIL2 - PLd

HME

Mercury Filled - HART - SIL2 - PLd

Main features
  • Pressure ranges from: 0-17 to 0-2000 bar / 0-250 to 0-30000 psi
  • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M)
  • Fluid-filled system for temperature stability
Find a distributor near you

Technical specifications

Overview

The HME series of Gefran, are pressure transmitters for using in High temperature environment and specifically designed for melt pressure measurement and available only to be used in large-scale fixed installations or in large-scale stationary industrial tools, typically extruders, or for laboratory B2B equipments for R&D purposes according to the European Directive 2011/65/EU.

The HME series of Gefran are pressure transmitters with HART communication protocol for using in high temperature environment.

The main characteristic of this series is the capability to read temperature of the media up to 400°C.

The constructive principle is based on the hydraulic trasmission of the pressure.

The fluid-filled system assures the temperature stability.

The physical measure is transformed in a electrical measure by means of strain-gauge technology.

  • Pressure ranges from: 0-17 to 0-2000 bar / 0-250 to 0-30000 psi
  • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M)
  • Fluid-filled system for temperature stability
  • Mercury filling volume: HME0 (30mm³); HME1, HME2, HME3 (40mm³)
  • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • Autozero function on board / external option
  • Standard diaphragm is 15-5 PH stainless steel with GTP+ coating
  • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi

Further versions available on request.