Field-Oriented vector inverter for Hoist & Crane applications, from 0.75kW up to 1.65MW
* Mains supply:
- 3 x 380…480Vac, 50/60Hz (-4 models )
- 3 x 690Vac, 50/60Hz (-6 models )
- 450…750Vdc (-DC-4 models)
- 600…1120Vdc (-DC-6 models)
* Motor ratings from 0.75kW (1Hp) to 1.65MW (2200Hp)
* Certifications: CE. UL, cUL
Functions:
Motor type: asynchronous
Self-tuning rotational and stand still of speed-current-flux regulators and motor data identification
Torque control
Simplified Start-up menu
Instantaneous Overload up to 180%
Motor, Drive and Braking resistor I2t thermal protection
100% torque at zero-speed
Braking management
Function hoist speed-up
Function Anti-Sway
Function Overtravel,
Function Anti impact
Function Master/Follower
Multispeed function (16 programmable preset)
4 independent programmable Multi-ramp
Double motor parameters setting
Joystick management
CT an VT operating mode
Memory Keypad with 5 parameters set
Options:
I/O expansion cards, configurable according to the customer's machine needs
Expansion cards for the management of auxiliary encoders
Field-bus interface cards: ProfiBus , CANopen, DeviceNet, GDNet, EtherCAT, Industrial Ethernet(*)
Safety Stop card in accordance with EN 954-1 (Cat.3) PL "e"
Braking resistors (standardized for the whole line)
Dedicated EMC filters (in compliance with CEE - EN61800-3:2004)
Input & Output chokes (standardized for the whole line)
OPT-485-ADV, RS485 optoinsulator for point-to-point/multidrop connections
BUy, External Braking Unit for drives power over 55kW
AFE200 Regen Active Front End power supply unit
KB-ADV Remotable keypad kit
Features:
Regulation control modes: FOC with Speed feedback, FOC open loop, V/F
Max Output frequency 500Hz
DC Choke integrated up to 132kW
EMC Filter integrated
Dynamic Braking Module integrated up to 55kW
Heavy duty and Light duty overload management
Up to 4 options on board
Multilanguage programming software (5 languages)
Alphanumeric programming keypad
2 Bipolar Analogue Inputs (Voltage/Current)
2 Bipolar Analogue Outputs (1: Voltage/Current, 1: Voltage)
6 Digital Inputs (PNP / NPN)
2 Digital Outputs (PNP / NPN)
2 Relay Outputs, single contact
RS485 Serial Line (Modbus RTU protocol)
Interfacing with the more common field bus: ProfiBus, CANopen, DeviceNet, EtherNet real.time GDNet, EtherCAT, Industrial Ethernet(*), ProfiNet
IP20 protection degree as standard (IP00 size 7 and parallel unit)
(*)Compatible to industry standards