TC2 Thermocouples with Interchangeable Insert for measure in industrial processes and furnaces
|
|
- Temperature limits:
-40 ... + 350°C for type T
-40 ... + 550°C for type J
-40 ... + 600°C for type E
-40 ... +1050°C for type K (see table for sheath diameters)
- Tolerance:
UNI 7938, IEC standards 584.2/Class 1:
for type T:
± 0,5° C (- 40 ... + 125° C)
± 0.004 [t] (t > + 125° C)
for type J, E, K:
± 1.5° C (- 40 ... + 375° C)
± 0.004 [t] (t > + 375° C)
- Mineral insulated interchangeable insert
- Application versatility
|